Demineralisation/Deionisation with Ion Absorption

MAK Water’s Deionisation (MAKPAK) Plants are designed to treat mains supplied potable water, with a typical conductivity of < 60 μS/cm, to produce high purity deionised water with a conductivity of < 3 μS/cm. The standard treatment process involves two mixed bed ion exchange vessels in series with a yes/no indicator positioned between vessel one and vessel two. When the conductivity of the water output from vessel one rises above 3 μS/cm, an alarm and visual indicator will alert an operator to take vessel one off line for change out, leaving the second vessel to stay online to continue treating.

Activated carbon can be added as a pre-treatment option to remove free chlorine from the feed water, there by extending the life of the resin. MAKPAKs are supplied as individual components and can be installed on site by MAK Water or a registered plumber.

If you have specific requirements, contact us about our custom water filtration systems.

STANDARD SPECIFICATIONS

Parameter Units Specification
Treated Water Volume   75,000 L per vessel (based on 60 µm/cm2 feed water)
Vessel Size mm 1,500 H 300 D
Flow Rate L/hr 1,300 (nominal)
Feed Water Conductivity µs/cm <60 (typical)
Treated Water Conductivity µs/cm <3 (typical)
Raw Water Temperature °C 15 ~ 35
Feed Water Inlet Pressure kPa >150<500 (typical)
Treated Water Discharge Pressure Drop kPa ~50 (typical)
Power Supply - Single phase, 240 V

STANDARD INCLUSIONS + OPTIONS

✓= Standard Supply, o = Optional Supply, - = Not Applicable

Equipment MAKPAK
Two MAKPAK Deionisation Vessles
Header Pipework and Barrel Union
Manual Isolation Valves
Pre-treatment – Activated Carbon o

 

Instrumentation Standard Package
Yes / No Indicator
Pressure Gauges o
Flow Gauges (Rotameters) o
Pressure Transmitters (4-20 mA) -
Flow Transmitters (4-20 mA) o
Conductivity Transmitter (4-20 mA) o

 

NOTE: Output from 4-20mA transmitters to connected to the control system by others.