Ultrafiltration – Basic

OVERVIEW

The Ultrafiltration (UF-B) plants are designed to treat surface water, tertiary treated effluent, storm water and waste water to achieve potable/process water or may be used as pre-treatment to reverse osmosis. They treat a wide range of highly variable waters with <50 NTU of turbidity and <100 mg/L of suspended solids.

The standard treatment process includes optional pre filtration (500 micron screen filter), Ultrafiltration process and automatic backwashing for membrane cleaning. Additional pre or post UF treatment steps may be added to suit feed or filtered water requirements such as iron removal, pH correction or sterilisation. The MAK UF plants are available as skid mounted units or containerised systems.

If you have specific requirements, contact us about our custom water filtration systems.

STANDARD SPECIFICATIONS

Parameter Units UF-B-20 UF-B-40 UF-B-60 UF-B-80
Filtrate Flow Rate(varies according to feed water quality) m3/day 20 40 60 80
Filtrate Recovery Rate % 90 – 98% (varies according to feed water quality)
Membrane Type - Outside in, dead end
Filtrate Turbidity NTU <0.1 (typical)
Raw Water Turbidity (max) NTU <50
Raw Water TSS  (max) mg/L <100
Feed pH range pH 6 – 9 (exposure to chlorine or chloramines is not recommended in feeds below pH 6.5)
Allowable pH range for chemical cleaning (by others) pH 2 - 10
Raw Water Temperature °C 15 ~ 35
Ambient Design Temperature °C 5 ~ 45 (-15 ~ 50 for insulated containerized system)
Feed-Pre Screen Requirements micron 500 or finer (unscreened or coarsely screened raw water may reduce membrane
operating life)
Feed Water Inlet Pressure (min) kPa 100 kPa
Feed Water Inlet Pressure (Max) kPa 200 kPa (recommend <150)
Filtrate Discharge Pressure Drop kPa ~30
Backwash Discharge Pressure Drop kPa ~20
Power Supply - AC 110/240 V, 1 Phase, 50/60 Hz
Power Consumption kW 0.5 0.5 0.5 0.5
No. Containers (Optional) - 1 x 10’ 1 x 10’ 1 x 10’ 1 x 10’

 

STANDARD INCLUSIONS + OPTIONS

✓= Standard Supply o = Optional Supply - = Not Applicable

Equipment UF-B-20 UF-B-40 UF-B-60 UF-B-80
Skid Mounted Plant & Equipment
Flow Control Vale
UF Feed Pump o o o o
Pre-filtration – Manual 500 Micron Screen o o o o
Automatic Membrane Backwash System
Control System with LCD graphic display
Containerized system, c/w A/C & Lights o o o o
Container Insulation (walls & ceiling) o o o o
Container non-slip floor coverings o o o o
Additional UV Sterlisation o o o o
Filtrate Distribution Pump Set o o o o

 

Instrumentation Standard Package
Pressure Gauges
Pressure Transmitters o
Flow Sensor o
Turbidity Transmitter o
Float Switches (Feed/Filtrate, Tanks) o

OPTIONS

  • CX - Contained system
  • FP - UF Feed Pump
  • SF - 500 Micron sreen filter
  • UV - UV sterilisation
  • DPS -  Filtrate distribution pump set

 