Technical Specifications

Standard Specifications

Parameter

Units

Lagoon Master Model

V1

V2

Blower mounting location  On top of unitOnshore
Installed powerkW3.04.4
Regenerative blowers (see note 1)Qty x kW2x 1.52x 2.2
Water moving capacityha0.4 to 1.6
Dissolved Oxygen inputkg O2/hup to 6.8 
Mixing ratem3/dup to 34,100 
Minimum required water depthm1.23 
Overall dimensions L x W x Hm2.26 x 2.44 x 1.602.26 x 2.44 x 1.22
Weight (see note 2)kg360230

 

Notes:
1. Both single phase and three phase blowers available
2. Including blowers for V1, without blowers for V2

Standard Inclusions and Options

= Standard Supplyo = Optional Supply- = Not Applicable

Equipment

Lagoon Master Model

V1

V2

Aerator frame and body in 316SS and HDPE, coarse diffuser bubble grid in 316SS and fine bubble diffuser diffuser grids in HDPE
Blowers with 316SS hose connection hardware and HDPE hoods (blowers mounted on aerator for V1 & located onshore for V2)
Air hoses EPDM, 2-inch ID, 3-ply, one per blower, standard length 15m eachN/A 
Stand for onshore mounted blowers in 316SSN/A
Mooring:Struts in 316SS, standard length 6.4 m, for fixing to embankment
Cables (6 mm) and fittings in 316SS, fixed 2 x concrete blocks on the floor of the pond/lagoon,
standard length 20m
o
Base skids in 316SS (see note 1)o
Power cable (see note 2), standard length 15mN/A


Instrumentation & Controls

V1

V2

Junction box, polycarbonate (see note 2)N/A
Control Box in 316SSoo

Notes:
1. Required where the aerator is used in ponds/lagoons with a synthetic liner.
2. For V1 only, connection between Junction Box and Control Box

Disclaimer: We continuously update and improve our products and services, contact us for more detailed information or to confirm specifications. MAK Water takes no responsibility for any errors resulting from the use of information contained on this website.