Demineralisation Deionisation with ion absorption
MAK Water’s Deionisation (MAKPAK) Plants are designed to treat mains supplied potable water, with a typical conductivity of < 60 μS/cm, to produce high purity deionised water with a conductivity of < 3 μS/cm. The standard treatment process involves two mixed bed ion exchange vessels in series with a yes/no indicator positioned between vessel one and vessel two. When the conductivity of the water output from vessel one rises above 3 μS/cm, an alarm and visual indicator will alert an operator to take vessel one off line for change out, leaving the second vessel to stay online to continue treating.
Activated carbon can be added as a pre-treatment option to remove free chlorine from the feed water, there by extending the life of the resin. MAKPAKs are supplied as individual components and can be installed on site by MAK Water or a registered plumber.


Technical Specifications
Standard Specifications
Parameter | Units | Specification | ||||||
---|---|---|---|---|---|---|---|---|
Treated Water Volume | 75,000 L per vessel (based on 60 µm/cm2 feed water) | |||||||
Vessel Size | mm | 1,500 H 300 D | ||||||
Flow Rate | L/hr | 1,300 (nominal) | ||||||
Feed Water Conductivity | µs/cm | <60 (typical) | ||||||
Treated Water Conductivity | µs/cm | <3 (typical) | ||||||
Raw Water Temperature | °C | 15 ~ 35 | ||||||
Feed Water Inlet Pressure | kPa | >150<500 (typical) | ||||||
Treated Water Discharge Pressure Drop | kPa | ~50 (typical) | ||||||
Power Supply | - | Single phase, 240 V |
Standard Inclusions and Options
Equipment | MAKPAK | |||||||
---|---|---|---|---|---|---|---|---|
Two MAKPAK Deionisation Vessles | ✓ | |||||||
Header Pipework and Barrel Union | ✓ | |||||||
Manual Isolation Valves | ✓ | |||||||
Pre-treatment – Activated Carbon | o |
Instrumentation | Standard Package | |||||||
---|---|---|---|---|---|---|---|---|
Yes / No Indicator | ✓ | |||||||
Pressure Gauges | o | |||||||
Flow Gauges (Rotameters) | o | |||||||
Pressure Transmitters (4-20 mA) | - | |||||||
Flow Transmitters (4-20 mA) | o | |||||||
Conductivity Transmitter (4-20 mA) | o |
NOTE: Output from 4-20mA transmitters to connected to the control system by others.
Water Filtration Systems
Related Solutions
Belt Filter
The Belt Filter provides effective mechanical filtration for removing solids from wastewater in a range of applications.

Multimedia Filtration
MAK Water’s Multimedia Filtration (MMF) plants are designed to treat ground water, surface water, tertiary treated effluent, storm water or wastewater with <30 mg/L of total suspended solids.

Cloth Media Filters
The MITA Water Technologies Cloth Media Filters (CMF) deliver effluent quality comparable to sand filters (TSS < 5 mg/L).

Ultrafiltration
MAK Water’s Ultrafiltration (UF) plants are designed to treat ground water, surface water, tertiary treated effluent, storm water or wastewater with turbidity <300 NTU.

Ultrafiltration-basic
Ultrafiltration (UF-B) plants are designed to treat surface water, tertiary treated effluent, storm water and waste water to achieve potable/process water or may be used as pre-treatment to reverse osmosis.

Water Softening with Ion Exchange
MAK’s Water Softening plants (WSP) are designed to reduce hardness from water sources that may have negative downstream implications such as scaling of pipework and equipment.